FieldLink: Units are Incorrect
FieldLink: Units are Incorrect
Problem: User has CAD and points appear in meters when he wanted imperial.
If a CAD file is imported into Trimble FieldLink “unitless” it will assume the units selected in TFL. Try the following fixes to resolve the issue either with a new file or directly inside of AutoCAD.
Text File Fix
- Have the file author or partner that you got the file from export a point file to a .txt and adjust the header to the correct units of measurement (meters or feet).
- Then change TFL units to the desired units of measurement ( meters or feets).
- Import the points and background ( the CAD file will assume the units of TFL) back into TFL and the point file will readjust upon importing with new header.
New CAD File with Selected Units
- If you have access to AutoCAD you can open the file and once open type in “Units”.
- A window will open up that will allow you to save the file to a given unit type.
- Select your preferred unit type and then resave the CAD file and use that new file in TFL.
Related Articles
Trimble FieldLink - Units are Incorrect
Trimble FieldLink - Units are Incorrect Problem: User has CAD and points appear in meters when he wanted imperial. Solution: If a CAD file is imported into Trimble Field Link "unitless" it will assume the units selected in TFL. Have customer export ...
FieldLink: v6.8 Release Notes
FieldLink: v6.8 Release Notes FieldLink v6.8 (2023-08 v6.8.0) has been released and ready to install via Trimble Installation Manager (TIM). Please see the support article about installing updates via TIM if you need help updating FieldLink. Please ...
TFL: "Import Failed - Invalid Data File Format"
TFL: "Import Failed - Invalid Data File Format" Problem: When importing a CSV/TXT file the user gets an error stating "IMPORT FAILED - INVALID DATA FILE FORMAT" Solution: This is caused by the format of the point file being incorrect. The point file ...
TFL: Import SKP File NOT Available
TFL: Import SKP File NOT Available Problem: When attempting to import a SketchUp model (SKP), the file is not being displayed in the "Import" menu. Solution: Trimble Field Link only accepts .skp files NOT .SKP files. To resolve, rename the file to ...
Trimble Access: Unable to import point file from Trimble Field Link
Trimble Access: Unable to import point file from Trimble FieldLink Problem: Customer was unable to import point file from Trimble Field Link into Access Solution: Access requires point files to not have header. Customer needs to remove header and ...