Robotic Total Station Angular Accuracy

Robotic Total Station Angular Accuracy


Robotic Total Station Angular Accuracy

Problem: Difference between 3" instrument and 5" instrument

Solution: If you are deciding between getting two instruments and your survey angles expected to be within of arc versus of arc for sights of
1500 ft the example below will give you a good idea of what level of accuracy will you achieve with different instruments:

If an angle is expected to be accurate to within (+/-) 1" for sights of 1500 ft, then the distance must be correct to within
1500(1")0.000004848 = (+/-) .007272 ft for compatibility.

If an angle is expected to be accurate to within (+/-) 3" for sights of 1500 ft, then the distance must be correct to within
1500(3")0.000004848 = (+/-) .021816 ft for compatibility.

If an angle is expected to be accurate to within (+/-) 5" for sights of 1500 ft, then the distance must be correct to within
1500(5")0.000004848 = (+/-) .03636 ft for compatibility.


    • Related Articles

    • Trimble RTS/S: Unable to Measure / Vibrating

      Trimble RTS/SPS: Unable to Measure / Vibrating Problem: Robotic Total Station tracks the prism, but position does not update on data collector either through the map or through measurements. Solution: This is often caused by the instrument vibrating ...
    • Trimble RTS/S/SPS: Field Columnation

      Trimble RTS/S/SPS: Field Columnation Problem: Steps for performing a field columnation on Trimble robotic instrument. Solution: To perform a Tracker Collimation. Set up a deadman (flat prism, on a tribrach attached to a tripod) at 100m. Set up the ...
    • Trimble X7: Station Connections Color Changed

      Trimble X7: Station Connections Color Changed Problem: After deleting a scan station inside of Trimble Field Link, the colors connecting the stations changed to (in this instance) green to red/yellow. Solution: The color of the connections is based ...
    • Trimble FieldLink: Not Live Updating Location

      Trimble FieldLink: Not Live Updating Location Problem: Trimble FieldLink will not update position within software, but instrument is being tracked. Solution: If user is running Trimble Field Link for Structures/MEP, they need to upgrade to Trimble ...
    • Rod Bubble Error Calculations Between Inverted Rod & Carbon Fiber

      Rod Bubble Error Calculations Between Inverted Rod & Carbon Fiber Problem: Why is there a difference in measurements between different rods on same location? Solution: The rod bubbles have different tolerances. Depending on the height above the ...